Developing Multi-biofunctional Polymeric Materials
Hyperbaric Material Modification System
​
NO Data Aquisition System
​
Perfusion pumps (stockert shiley roller pumps)
Add some more info about this item...
Multiflow roller pumps
Direction of rotation: clockwise and counterclocwise
RPM control range: 4 to 250 RPM
RPM display range: 0 to 250 RPM
RPM readout accuracy: +/- 0.04
LPM display range: 0 to 9.99 LPM
pH meter
pH Mode: 0.00 to 14.00pH with resolution of 0.01 and accuracy of ±0.01pH
Temperature Mode (with ATC probe): 0.0 to 100°C with resolution of 0.1°C and accuracy of 0.3°C
mV Mode (S90525, S90527 and S90528 only): -1000.0 to +1000.0 with a resolution of 0.1 and an accuracy of 0.1mV within ±199.9mV; 1mV beyond ±199.9mV
mV models also feature recorder output
Simple push-button standardization with auto-buffer recognition
Icons clearly show current meter status
Three-point calibration with percent slope calculation
Simple user-interface
Pipettes
Eppendorf Pipette Stands, Carousels and Chargers.
The pipettes can be attached by the handle, not the nose cone, which eliminates cross contamination from the stand to the pipette.
Stirring hotplate and Balance
Stirring plate:
Top plate dimensions range from 4" x 4" to 12" x 12"
Temperature selection ranges from 41 to 1004F
Stirring speeds to 1500 rpm
Capacities up to 80 lbs
Analytical balance:
Dependable mass measurement for solution preparations.
Capacity, 200g; Readability, 0.1mg; Repeatability, 0.1mg; Linearity, 0.3mg;
Weighing units: grams, Newtons
Simplicity Ultrapure water filter
The Simplicity system delivers ultrapure (type 1) water from pretreated water (distilled, deionized or reverse osmosis) to laboratories requiring < 5 liters of ultrapure water per day. Applications include preparation of blanks and standard solutions for a variety of analytical procedures. Built-in UV lamp. Dimensions: 14.2" x 11.4" x 20.1" (LxWxH). Operating weight: 18 to 20 lbs. 100 -230V, 50/60Hz.
Bioreactor flow cell
The flow cell is a bioreactor system to evaluate blood/biomaterial biocompatibility.
Regulated gas delivery
Medical grade oxygen and nitrogen gas delivery lines
Innova incubator
INNOVA 4200 shaker offers a wide temperature range of 5°C above ambient to 80°C.
Its large viewing window provides clear chamber visibility, minimizing the need to open the door. Its rapid air circulation also produces quick temperature recovery. Moreover, an in-chamber, moisture-proof receptacle secures power for accessories including rockers, rollers, or secondary shakers.
Microbio Lab
​
Fabrication Lab
​
EVOS FLoid
Multi-protocol enabled user-friendly EVOS Floid
Cell Imaging Station
Tube revolver
Tube Revolver can be used in a variety of laboratory fields such as Molecular Biology, Biochemistry, Clinical, and Histochemistry. The rotisseries are interchangeable so that the unit works with a variety of tube sizes. The four rotisserie paddles can be mixed for a combination of different tubes. Each paddle direction can be independently adjusted from 0-90 degrees.
UV-Vis
Thermo Scientificâ„¢ GENESYS 10S UV-Vis spectrophotometer utilizes a high-intensity xenon lamp and dual-beam optical geometry to deliver unsurpassed data quality. Firing pulses of light only when the instrument is taking a measurement, the xenon lamp provides strong illumination from the UV to the near-IR region of the spectrum.
Purge vessel
The Sievers Nitric Oxide Analyzer (NOA 280i) and purge system measures nitric oxide and its reaction products, nitrite, nitrate and nitrosothiols, in virtually any biological fluid including: cell culture media, plasma, sera, urine, cerebral-spinal fluid, bronchial-alveolar lavage, perfusates, and tissue homogenates.
Transonic flowmeter
The Transonic Tubing Flowmeter Module is used with Flowsensors to measure fluid flow in laboratory tubing.
Z1 dual threshold coulter counter
The Z1â„¢ Dual Threshold model is designed for platelet applications and for working with numerous cell types of variable sizes. It incorporates an oil displacement pump which delivers a high degree of accuracy and precision and eliminates the need for mercury. It allows for absolute cell counts or concentration, storage of up to five analysis settings, and a constant current feature which eliminates calibration drift.
Centrifuge
Sievers Nitric Oxide Analyzer
The Sievers Nitric Oxide Analyzer (NOA 280i) is a detection system for Nitric Oxide (NO) analysis. It uses ozone-chemiluminescence technology to conduct liquid and exhaled breath nitric oxide (NO) measurement. The Sievers NOA can be used to measure liquid samples or exhaled breath samples of nitric oxide.
Liquid Samples
The NOA 280i measures nitric oxide, nitrite, nitrate or nitrosothiols in most biological samples. Concentrations, ranging from low nanomolar to millimolar levels, can be measured in sample volumes ranging from a few microliters to several milliliters.
Exhaled Breath Samples
Exhaled nitric oxide can easily be measured with the NOA 280i. Fast response time and low sample flow rates allow for measurement of exhaled NO in humans and animals.